QQ email: xiongbacarrey@qq.com
ABB 5SHX2645L0004 PFTL101BE 2.0KN 3BSE004214R1 SUE3000 1VCF750090R804 PM511V16 3BSE011181R1 PP865A 3BSE042236R2 AO2000 LS25 UUD148AE02 PM866K01 3BSE050198R1 UFC760BE141 3BHE004573R0141 5SHY3545L0014UFC760BE143 3BHE004573R0143 XVC770BE101 3BHE021083R0101 5SHY4045L0006 3BHB030310R0001 3BHE039203R0101 GVC736CE101 5SHY3545L0010 3BHB013088R0001 3BHE009681R0101 GVC750BE101 5SHY6545L0001 AC10272001R0101 5SXE10-0181 PCD235B1101 3BHE032025R1101 UFD203A101 3BHE019361R0101 UAD142A01 3BHE012551R0001 PFXA401SF 3BSE024388R4 PFVK135 3BSE007135R1 PFTL201C 3BSE007913R50 50KN PFTL201C 10KN 3BSE007913R0010 PFTL101BE 2.0KN 3BSE004214R1 PFTL101B 5.0KN 3BSE004191R1 PFTL101B 20KN 3BSE004203R1 PFTL101B 2.0KN 3BSE004185R1 PFTL101A 1.0KN 3BSE004166R1 PFSK164 3BSE021180R1 The eight voltage monitor inputs and switch outputs operate at 15 to 60 volts DC voltage. Figure 2- FBM240 with relay output TA, displaying internal read back and output contact status read back redundant contact output function block COUTR for output. The output write and initialization logic redundant channels processed by the COUTR block. At each write of the COUTR block, the same output write is sent to two modules, making full use of the fieldbus and the logic circuit units of each module. You can choose to continuously output after the block input or pulse output with selectable pulse width. When a fault is detected in one of the modules, its output is marked as BAD, and the corresponding channel in the module automatically continues to drive the discrete output. Each output channel drives an external power supply load. Each FBM240 power module is equipped with a diode OR in the redundant adapter to help ensure redundant power. The microprocessor of each module executes digital output application programs and verifies diagnostic routines for FBM health. Configurable options for fault protection output safety include: ? Digital output fault protection fallback data - specify channel fallback values (0 or 1) for each of the eight digital outputs ? Mask options - determine which of the eight digital outputs maintains its current value and which outputs use fallback values ? Fieldbus fault protection delay time - FBM wait for communication length from CP before entering a communication fault
For redundant modules, the fail safe backup data and mask options are configurable. An additional option is provided so that module data will fall back to zero (0) when the module is offline due to maintenance functions, thus not interfering with the remaining modules that are still online. FBM240 requires firmware version 1.40N or higher to support this feature. For a single module, the fail safe fallback data and mask options are configurable. The standard design of this module features a sturdy extruded aluminum casing that can be applied to circuits. The housing designed specifically for installing FBM provides various levels of G3 harsh environments that comply with ISA standard S71.04. The redundancy of high availability module pairs, coupled with high fault coverage, provides a very high subsystem availability time. This module performs the signal conversion required for interface electrical input signals from field sensors to optional redundant field buses. It executes discrete I/O programs with configurable options such as input filtering time, fault protection configurationPFSK162 3BSE015088R1 PFSK160A 3BSE009514R1 PFSK152 3BSE018877R1 PFSK151 3BSE018876R1 PFSK142 3BSE006505R1 PFSK130 3BSE002616R1 PFSA140 3BSE006503R1 PFEA113-20 3BSE028144R0020 PFEA113-65 3BSE050092R65 PFEA112-65 3BSE050091R65 PFEA112-20 3BSE030369R0020 PFEA111-65 3BSE050090R65 PFEA111-20 3BSE050090R20 PFCA401SF 3BSE024387R4 MPRC086444-003